NEC Electra Elite IPK II Installation And Maintenance Manual
NEC Electra Elite IPK II Installation And Maintenance Manual

NEC Electra Elite IPK II Installation And Maintenance Manual

H.323 trunk
Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Notice
Note that when converting this document from its original format to a
.pdf file, some minor font and format changes may occur. When
viewing and printing this document, we cannot guarantee that your
specific PC or printer will support all of the fonts or graphics.
Therefore, when you view the document, fonts may be substituted and
your individual printer may not have the capability to print the
document correctly.

Advertisement

Table of Contents
loading

Summary of Contents for NEC Electra Elite IPK II

  • Page 1 Notice Note that when converting this document from its original format to a .pdf file, some minor font and format changes may occur. When viewing and printing this document, we cannot guarantee that your specific PC or printer will support all of the fonts or graphics. Therefore, when you view the document, fonts may be substituted and your individual printer may not have the capability to print the document correctly.
  • Page 3 H.323 T RUNK ARDWARE NSTALLATION AINTENANCE ANUAL I N T - 1 0 7 4 ( I P K I I ) O C U M E N T E V I S I O N...
  • Page 5 Contents of this manual are subject to change without prior notice at the discretion of NEC Unified Solutions, Inc. This document has been prepared for the use of employees and customers of NEC Unified Solutions, Inc. and may not be reproduced without prior written approval of NEC Unified Solutions, Inc.
  • Page 7: Table Of Contents

    TABLE OF CONTENTS ___________________________________________________________________________________ Chapter 1 Electra Elite IPK II IAD(8)-U( ) ETU Section 1 Description ................... 1-1 Section 2 Indicators, Switches, and Connectors ..........1-2 2.1 LED Indicators ..................1-2 2.1.1 Status LED ....................1-2 2.1.2 Hot Swap ....................1-2 2.1.3...
  • Page 8 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ Section 2 PC Parameters ..................4-1 Section 3 Sample Setup Procedure ..............4-2 Section 4 Shutdown Procedure ................4-3 Appendix A Web-Based Setup and Configuration Section 1 Accessing Web-Based Setup ............. A-1 Section 2 Card Configuration Program Menus ..........
  • Page 9 H.323 Trunk Document Revision 1 ___________________________________________________________________________________ Section 3 Port Settings ..................A-6 Port Number ..................... A-6 Encoding Preferences: ..................A-6 Packet Size (ms) ....................A-6 Jitter Depth (ms): ....................A-7 Section 4 Address ....................A-8 Section 5 Station Settings .................. A-9 Caller ID ......................
  • Page 10 Appendix D Electra Elite IPK II IAD(8)-U( ) ETU Installation Section 1 Introduction ..................D-1 Section 2 Installing IAD(8)-U( ) ETU Package ........... D-1 2.1 Description ..................D-1 2.2 Installing the ETU in the Electra Elite IPK II KSU ......D-2 ___________________________________________________________________________________ Table of Contents...
  • Page 11 LIST OF FIGURES AND TABLES ___________________________________________________________________________________ Table 1-1 IAD(8)-U( ) LED Boot Sequence Indications ..............1-2 Table 1-2 IAD(8)-U( ) Switch Settings ..................1-3 Table 4-1 Factory Network Settings ....................4-1 Table 4-2 Network Settings for the PC ..................4-1 Figure A-1 Web Browser Login Screen ..................
  • Page 12 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ List of Figures and Tables...
  • Page 13: Electra Elite Ipk Ii Iad(8)-U( ) Etu

    ECTION ESCRIPTION The IAD(8)-U( ) ETU is an optional interface package for Electra Elite IPK II KTS that can combine trunk and tie line calls into H.323 trunks. This ETU can be assigned as a 2-port TLI(2)-U10, 4-port DID (4)-U10, 4-port or 8-port DTI-U10 ETU, COI/ COID(4)-U10, or 8-port COI/COID(8)-U10.
  • Page 14: Indicators, Switches, And Connectors

    Document Revision 1 H.323 Trunk ___________________________________________________________________________________ Refer to the Appendix D Electra Elite IPK II IAD(8)-U( ) ETU Installation instructions for installing the IAD ETU. ECTION NDICATORS WITCHES ONNECTORS LED Indicators The total of nine LEDs on this ETU are described in...
  • Page 15: Switch Settings

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ Switch Settings The IAD(8)-U( ) ETU has two switches that are described below. Switch S1 is a Press to Reset switch. Switch S2 is a Card Configuration switch. Refer to Table 1-2 IAD(8)-U( ) Switch Settings.
  • Page 16: Pushbutton Switch

    S1 is the reset switch. Environmental Conditions The following environmental conditions apply for IAD (8)-U( ) ETU operation: Operating Temperature: +32 to 104°F (0 to 40C) Operating Humidity: 10% to 90 % (non-condensing) ___________________________________________________________________________________ 1 - 4 Electra Elite IPK II IAD(8)-U( ) ETU...
  • Page 17: Ipk Ii Iad(8)-U( ) Etu Setup

    The IAD(8)-U( ) ETU can be viewed and installed like any other ETU used in the KTS system. Refer to Appendix D Electra Elite IPK II IAD(8)-U( ) ETU Installation. However, the CAT5 Ethernet cable plugs into the Ethernet connector on the front of the ETU, and not through the regular connections as with other interface boards.
  • Page 18 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ 2 - 2 IPK II IAD(8)-U( ) ETU Setup...
  • Page 19: Ipk Ii Iad(8)-U( ) Programming

    YSTEM ROGRAMMING The IAD (8)-U10 ETU is recognized by the Electra Elite IPK II system as a COI(4)/ (8)-U10 ETU, a COID(4)/(8)-U10 ETU, a DID(4)-U10 ETU, or a TLI(2)-U10 ETU, DTI ETU based on the configuration on the ETU. This ETU takes longer to initialize than the other Electra Elite IPK II ETUs.
  • Page 20 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ Examine the IAD board and verify the DIP switch settings. Repeat steps 1-3. The IAD(8)-U10 ETU consumes trunk ports according to the configured type of card (based upon DIP switch settings). The IPK II recognizes all DTI( ) cards as DTI(24).
  • Page 21: Ipk Ii Iad(8)-U( ) Configuration

    IPK II IAD(8)-U( ) Configuration C h a p t e r 4 ___________________________________________________________________________________ IAD(8)-U( ) ETU ECTION ONFIGURING When installed for the first time, the IAD(8)-U( ) ETU, comes up with factory set default parameters as shown in Table 4-1 Factory Network Settings Table 4-1 Factory Network Settings neciad Computer Name...
  • Page 22 Set the card type according to the settings specified in Table 1-2 IAD(8)-U( ) Switch Settings on page 1-3 and then install the ETU in the Electra Elite IPK II KSU. Boot up the statically assigned Host PC. Connect to the IAD (8)-U( ) ETU via your Web Browser.
  • Page 23: Shutdown Procedure

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ When the user dials any number beginning with 214 (e.g., 2145551234), the call is routed to a IAD(8)-U() ETU with IP Address 10.1.0.100. When all parameters have been configured, select Submit. Select the System tab, then select the Reset the Card option. The ETU goes through a reboot cycle and may take a few minutes.
  • Page 24 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ 4 - 4 IPK II IAD(8)-U( ) Configuration...
  • Page 25: Appendix A Web-Based Setup And Configuration

    Web-Based Setup and Configuration A p p e n d i x A ___________________________________________________________________________________ This chapter describes all the screens used during the configuration of the IAD (8)-U( ) ETU with H.323 Trunk Package installed. ECTION CCESSING ASED ETUP The IAD(8)-U( ) ETU H.323 Trunk Application is configured using an internet browser.
  • Page 26 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ Start your Internet Explorer from a PC that is connected to the same network as the IAD(8)-U( ) ETU. The IAD(8)-U( ) ETU default IP Address 192.168.1.100. Enter the default IP Address in the address link of your browser. When the login screen appears enter the Login ID and password.
  • Page 27: Host Name: (Default Value: Neciad

    Starting RTP Port Number: Default value: (49150) Use this field to specify the RTP port number to be used. NEC recommends leaving this field in its default value, unless otherwise required by the network administrator. Country: (Default value: North America) Choose the country where this card will be operating.
  • Page 28: Signaling Tos: (Default Value: 0Xc0

    Document Revision 1 H.323 Trunk ___________________________________________________________________________________ Signaling TOS: (Default value: 0xC0) IAD(8)-U( ) ETU sets this value (in Hex) in the 1-byte TOS field for outgoing H.323 messaging UDP packets. Refer to IETF RFC791 and subsequent RFCs describing the usage of TOS field in the Internet. Page Timeout: (Default value: 10 minutes) The page timeout setting applies to the time Web Configuration Utility remains active.
  • Page 29: Use Gatekeeper

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ H.323 Gatekeeper Settings Use Gatekeeper: Check this field to use an H.323 gatekeeper. Auto Discovery: By checking this field, the IAD(8)-U() ETU determines the IP address of the H.323 gatekeeper automatically. Automatic discovery is accomplished if the host and gatekeeper are in the same network.
  • Page 30: Port Settings

    Document Revision 1 H.323 Trunk ___________________________________________________________________________________ ECTION ETTINGS Using this screen, the voice over IP encoding parameters can be set per channel (or port). Figure A-3 Port Setting Parameters Port Number This identifies the port or channel number. Encoding Preferences: Select the preferred encoding protocol (codec) for making outgoing calls.
  • Page 31: Jitter Depth (Ms

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ The calling party side codec in an incoming call ‘INVITE” request will be matched against the preferences set in this page, starting from preference 1. If a matching codec is found the call will be accepted, with the packet size set in the receiving side. The matching process does not apply if the “Use all available codecs for incoming calls”...
  • Page 32: Address

    Document Revision 1 H.323 Trunk ___________________________________________________________________________________ ECTION DDRESS This table defines the destination of an outgoing call using the IAD(8)- U( ) ETU. When the first dialed digits on an outgoing call match any of the numbers in the Dialed Number column, that call is routed to the applicable IP address.
  • Page 33: Station Settings

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ ECTION TATION ETTINGS The Station Settings table only applies to the IAD(8)-U( ) configured for COI/COID/ DTI-ANI mode. Figure A-5 Port Parameters Caller ID This field provides the Caller Name for the called party in outgoing calls. For example, if Trunk 1 makes a successful outgoing call;...
  • Page 34: Access Codes

    Figure A-6 Access Code Parameters The contents (entries) in this table must correspond with valid access codes programmed in Memory Blocks 11-09-xx Trunk Access Code Assignment.. Refer to the Electra Elite IPK II Programming Manual. ___________________________________________________________________________________ A - 10 Web-Based Setup and Configuration...
  • Page 35: Tracing

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ ECTION RACING This page is used for analyzing any communication errors, and is intended for use by any technical support personnel. Figure A-7 Tracing Information The tracing functions are not enabled at default. Consult your Technical Support prior to enabling these functions.
  • Page 36: System

    Document Revision 1 H.323 Trunk ___________________________________________________________________________________ ECTION YSTEM This page provides information about the firmware revision, card type and additional administrator functions. Figure A-8 System Parameters The system page will provide access to five administrator functions. Reset Card Upload Reset Password Save System Restore System ___________________________________________________________________________________...
  • Page 37: Reset Card

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ ECTION ESET A reset is necessary when changing the operating modes and network parameters (such as IP address, Subnet mask, gateway address, TOS field etc.). Figure A-9 Resetting the Card Safe reset - When safe reset is selected, the IAD(8)-U( ) will only execute the reset after all channels or ports are idle.
  • Page 38: Section 10 Upload

    When Upload is selected, you are prompted to enter the path name where the trunk card package is located. Press Upload. Once the upload is completed, the IAD(8)- U( ) ETU must be reset. This firmware is provided by NEC and must be stored on your local PC prior to firmware upload. ___________________________________________________________________________________...
  • Page 39: Section 11 Reset Password

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ ECTION ESET ASSWORD Enables the "admin" user to change the current password. You cannot change the user name from "admin". Figure A-11 Reset Password Parameters When changing the password a maximum of 12 alphanumeric characters may be used for the password.
  • Page 40: Section 12 Save System

    Document Revision 1 H.323 Trunk ___________________________________________________________________________________ ECTION YSTEM This option is used to save the H.323 trunk configuration file to a floppy disk or hard drive on the local programming PC. Select the NecIadConfiguration.iad hyperlink. Do not change the file extension from .iad. Figure A-12 Save System Parameters ___________________________________________________________________________________ A - 16...
  • Page 41: Section 13 Restore System

    H.323 Trunk Document Revision 1 ___________________________________________________________________________________ ECTION ESTORE YSTEM This option enables previously saved H.323 trunk configuration files (saved from Save System link) to be restored. Figure A-13 Restore System Parameters Supply the file name for the saved configuration file. Select Restore. The system requires a card reset after configuration has been restored.
  • Page 42 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ A - 18 Web-Based Setup and Configuration...
  • Page 43: Appendix B Troubleshooting

    ECTION NTRODUCTION The IAD(8)-U( ) (H.323 trunk) ETU reacts to the other parts of the Electra Elite IPK II system exactly like its operating mode. For example, if the H.323 Trunk ETU is configured in DID mode in the KSU, it is treated as any other regular DID(4)-U10 ETU.
  • Page 44 IAD(8)-U( ) ETU. For example, if the IAD(8)-U( ) ETU is in slot 3 of cabinet 1 and operating as a COID(8)-U10 ETU, the Electra Elite IPK II system must be programmed, using a PC or handset, for a COID(8)-U10 ETU in slot 3 of cabinet 1.
  • Page 45 H.323 Trunk Document Revision 1 ___________________________________________________________________________________ Point the Internet Explorer (Version 6.0 or higher) on the PC to 192.168.1.100 by typing this address in the navigation bar. When you upload a package while in factory default mode, all configured data will be lost, and default settings apply. ___________________________________________________________________________________ Hardware, Installation and Maintenance Manual B - 3...
  • Page 46 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ B - 4 Troubleshooting...
  • Page 47: Appendix C Glossary

    Glossary A p p e n d i x C ___________________________________________________________________________________ The following terms are used within this document. Term Definition The packet switched network that was originally designed for data traffic (non- Data Networks speech). Digital signal processor (a reduced instruction set processor designed to perform voice compression more efficiently than a general use processor like Pentium).
  • Page 48 Document Revision 1 H.323 Trunk ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ C - 2 Glossary...
  • Page 49: Appendix D Electra Elite Ipk Ii Iad(8)-U( ) Etu Installation

    ACKAGE Description The IAD(8)-U( ) ETU is an optional interface for the Electra Elite IPK II KSU that is used as integration device. The IAD(8)-U( ) ETU will support various IP applications (e.g., IP CCH ETU application, H.323 Trunk card application, and Megaco Station application).
  • Page 50: Installing The Etu In The Electra Elite Ipk Ii Ksu

    H.323 Trunk ___________________________________________________________________________________ Installing the ETU in the Electra Elite IPK II KSU When the IAD(8)-U( ) ETU is used for the H.323 Trunk card application, this ETU is assigned in the KSU as an ETU. This ETU has eight ports, and installed in slots S1~S8 of the KSU.
  • Page 51 H.323 Trunk Document Revision 2 ___________________________________________________________________________________ The IAD(8)-U( ) Card Default IP Address is: 192.168.1.100. Set your PC so that it is statically assigned an IP address of 192.168.1.xxx with a subnet mask of 255.255.255.0 to ensure it is in the same network as the IAD(8)-U( ) ETU. Point the Internet Explorer (Version 6.0 or higher) on the PC to 192.168.1.100 by typing this address in the navigation bar.
  • Page 52 Upload the applicable IP Application package (e.g., trunk card package, H.323 trunk card and station card package). Select Upload. This firmware is provided by NEC and must be stored on your local PC prior to firmware upload. Figure D-3 Welcome Screen...
  • Page 53 H.323 Trunk Document Revision 2 ___________________________________________________________________________________ Congratulations, you have successfully loaded your application package. Wait until the following screen is displayed. Figure D-4 ETU Successfully Loaded Message You can now remove the IAD(8)-U( ) ETU and configure the Dip Switch Setting to the applicable Mode of operation (if so required by the package you loaded).
  • Page 54 Document Revision 2 H.323 Trunk ___________________________________________________________________________________ THIS PAGE INTENTIONALLY LEFT BLANK ___________________________________________________________________________________ D - 6 Electra Elite IPK II IAD(8)-U( ) ETU Installation...
  • Page 56 H . 3 2 3 T R U N K H A R D W A R E , I N S T A L L A T I O N , A N D M A I N T E N A N C E M A N U A L N E C U n i f i e d S o l u t i o n s , I n c .

Table of Contents