VoIP DSP Resource
10-19-01
VoIP DSP Resource Selection (Version 1600 or higher required)
Select type of VoIP ETU DSP Resource. This program setting has no affect on the terminal/
trunk port assignment or usage.
Entries: 0 = Common (Used for both IP Extensions and Trunks), 1 = Extension, 2 = Trunks, 3 =
Networking.
(Default: 0)
10-40-02
VoIP Trunk Availability – Number of Ports (Version 1600 or higher required)
0 = 4 ports
1 = 8 ports
2 = 12 ports
3 = 16 ports
(Default: 0)
SIP Authentication Information
10-30-02
SIP Authentication Information – User Name
Define the authentication User name provided by the SIP carrier.
Entries: 48 characters maximum
(Default: None)
10-30-03
SIP Authentication Information – Password
Enter the authentication password provided by the SIP carrier. When the Electra Elite IPK II
registers its own ID with the carrier SIP server or makes an outgoing call via the carrier SIP
server, the SIP server requests the authentication. This data is used as Register ID 0.
Entries: 24 characters maximum
(Default: None)
10-30-04
SIP Authentication Information – Authorization Trial
Define the Authorization Trial. When a call tries to register with the SIP carrier and they refuse,
this entry determines how many times the Electra Elite IPK II sends authorization.
Entries: 1~9
(Default:1 time)
SIP Caller ID
14-01-24
Basic Trunk Data Setup – Trunk-to-Trunk Outgoing Caller ID Through Mode
Enable (1)/Disable (0) the Trunk-to-Trunk Outgoing Caller ID Through Mode. This option allows
Caller ID from the original outside caller to be displayed when a trunk is forwarded off premise.
This option can be used only with PRI and SIP trunks.
(Default: 0)