NEC Electra Elite IPK II System User Manual page 985

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Electra Elite IPK II
24-04-01
Automatic Trunk-to-Trunk Transfer Target Setup
Assign the Speed Dialing number (0~1999) to be used as the destination for the Trunk-to-Trunk
Transfer.
Trunks: 1~200
(default: 1999)
25-07-07
System Timers for VRS/DISA – Long Conversation Warning Tone Time
Determine the time (0~64800 seconds) a DISA caller or any trunk-to-trunk (such as Tandem
Trunking) conversation can talk before the Long Conversation tone is heard.
(default: 3600)
25-07-08
System Timers for VRS/DISA – Long Conversation Disconnect
This timer (0~64800 seconds) determines the time the system waits before disconnecting a
DISA or any trunk-to-trunk (such as Tandem Trunking) call after the Long Conversation tone is
heard.
(default: 10)
Trunk Disconnect Continue/Disconnect Codes
14-01-25
Basic Trunk Data Setup – Continued/Discontinued Trunk-to-Trunk Conversation
When Program 24-02-10 is set to disconnect a trunk after the defined time, determine whether
or not a user should have the ability to use the continue/disconnect code.
0 = Disabled
1 = Enabled
(default: 0)
20-28-01
Trunk to Trunk Conversation – Conversation Continue Code
When Program 14-01-25 is enabled, determine the 1-digit code the user should dial (0~9,
to extend the conversation length for the time defined in 20-28-03. If the Continue and
Disconnect codes are programmed the same (e.g., #), the system follows the Continue
operation. Using the Continue code before the warning tone is heard has no effect.
(default: No Setting)
20-28-02
Trunk to Trunk Conversation – Conversation Disconnect Code
When Program 14-01-25 is enabled, determine the 1-digit code the user should dial (0~9,
to immediately disconnect their call. Using the Disconnect code before the warning tone is heard
disconnects the call.
(default: No Setting)
20-28-03
Trunk to Trunk Conversation – Conversation Continue Time
When Program 14-01-25 is enabled, determine the time (0~64800 seconds) a call is extended
when the user dials the Continue code (defined in PRG 20-28-01).
(default: 0)
24-02-07
System Options for Transfer – Trunk-to-Trunk Transfer Release Warning Tone
This timer (0~64800 seconds) starts when a trunk begins talking with another trunk (for
example: Trunk-to-Trunk Transfer/Tandem Trunking). When this timer expires, a warning tone
is heard. If Program 24-02-10 is set, the conversation disconnects after that timer expires. This
timer is set again when the external digit timer expires. One of the trunks used must be an
analog trunk (or leased line).
(default: 1800)
Tandem Trunking (Unsupervised Conference)
Document Revision 4C
, #)
, #)
2 - 961

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents