For Printing System Information Reports
90-13-01
System Information Output – Output Port Type
Indicate the type of connection system information.
0 = No Setting (default)
1 = COM Port (CPUII)
2 = -- Not Used --
3 = LAN port (CPUII)
4 = CTA/CTU
90-13-02
System Information Output – Destination Extension Number
If the output port type (PRG 90-13-01) is set to CTA, enter the extension number with the CTA
connection.
Extension Number (up to eight digits)
No default is assigned
90-13-03
System Information Output – Output Command
Dial 1 from this program to send the system report to the connected device.
0 = Disable (Off) (default)
1 = Enable (On)
For E-mailing Alarm Reports
10-12-01
CPUII Network Setup – IP Address
1.0.0.1 ~ 126.255.255.254
128.1.0.1 ~ 191.254.255.254
192.0.1.1 ~ 223.255.254.254
Default = 172.16.0.10
10-12-02
CPUII Network Setup – Subnet Mask
128.0.0.0
240.0.0.0
254.0.0.0
255.192.0.0
255.252.0.0
255.255.128.0
255.255.248.0
255.255.255.0
255.255.255.224
255.255.255.252
192.0.0.0
248.0.0.0
255.0.0.0
255.224.0.0
255.254.0.0
255.255.192.0
255.255.252.0
255.255.255.128
255.255.255.240
255.255.255.254
224.0.0.0
252.0.0.0
Alarm Reports