Document Revision 4C
10-20-01
LAN Setup for External Equipment – TCP Port
Define the TCP port (0~65535) when communicating to the SMDR (type 5).
(default: 0)
10-20-03
LAN Setup for External Equipment – Keep Alive Time
Set keep alive time (0~255 seconds).
(default: 30)
10-21-02
CPUII Hardware Setup – Baud Rate for COM Port
If the SMDR connection is made using the COM port on the CPUII, define the baud rate.
Baud Rates:
0 = 4800
1 = 9600
2 = 19200 (default)
3 = 38400
14-01-06
Basic Trunk Data Setup – SMDR Printout
For each trunk, enter 1 if trunk calls should appear on SMDR report. Enter 0 if trunk calls should
not appear on SMDR report.
(default: 0)
15-01-03
Basic Extension Data Setup – SMDR Printout
For each extension, enter 1 if extension calls should appear on SMDR report. Enter 0 if
extension calls should not appear on SMDR report.
15-02-19
Multiline Telephone Basic Data Setup – CTA Data Communication Mode
Select 0 if the dip switch settings are set to PC connection or select 1 if printer/SMDR
connection is selected on the CTA/CTU adapter.
(default: 1)
15-02-20
Multiline Telephone Basic Data Setup – Baud Rate for CTA Port
Set the baud rate to be used by the CTA.
Baud Rates:
0 = 4800
1 = 9600
2 = 19200 (default
35-01-01
SMDR Options – Output Port Type
Specify the type of connection used for SMDR. The baud rate for the COM port should be set in
PRG 10-21-02 or PRG 15-02-20.
Connection Types:
0 = No Setting (default)
1 = COM (CPUII)
3 = LAN (CPUII LAN output)
4 = CTA/CTU
35-01-02
SMDR Options – Output Destination Number
Specify the SMDR printer output port (CTA/CTU extension number – up to 8 digits).
(default: No Setting)