NEC Electra Elite IPK II System User Manual page 487

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Electra Elite IPK II
Timer
Timer
Class 0
Class 1~15
25-07-08
20-31-20
25-07-09
20-31-21
25-07-10
20-31-22
31-01-02
20-31-23
Conditions
Timer Classes are used for CAR/VE also.
When Timer Class is set to 0 it uses the system-wide timers.
All stations and trunks are assigned to Timer Class 0 at default.
Both system-wide timers (Timer Class 0) and Timer Class timers (Timer Class 1~15) can
be used in the same system.
Default Setting
Timer Class set to 0 for all trunks and extensions.
System Availability
Terminals
All Multiline Terminals
Flexible Timeouts
Title
Long Conversation
Disconnect
DISA Internal Paging Time
DISA External Paging Time
Page Announcement
Duration
Comment
This determines the time the system waits before
disconnecting a trunk-to-trunk conversation call
after the Long Conversation tone is heard. Trunk
Timer Class is referred.
This is the maximum time for an Internal Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
This is the maximum time for an External Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
This timer sets the maximum time for External
Page announcements. Station or Trunk Timer
Class is referred by the caller makes
announcement.
Document Revision 4C
2 - 463