Members; Table 131: Show Chassis Environment Fpc Output Fields - Juniper JUNOS OS 10.3 - SOFTWARE Manual

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Required Privilege
Level
List of Sample Output
Output Fields

Table 131: show chassis environment fpc Output Fields

Field Name
Field Description
Status of the FPC:
State
(M40e and M160 routers only) Temperature of the air flowing past the FPC.
Temperature
(M320 routers only) Temperature of the air flowing into the chassis.
Temperature Intake
(T Series routers only) Temperature of the air flowing past the top of the FPC.
Temperature Top
(M120 and M320 routers only) Temperature of the air flowing out of the chassis.
Temperature Exhaust
(T Series routers only) Temperature of the air flowing past the bottom of the FPC.
Temperature Bottom
Copyright © 2010, Juniper Networks, Inc.
EX3200 switches and EX4200 standalone switches—Replace
EX4200 switches in a Virtual Chassis configuration—Replace
from 0 through 9 (switch's member ID).
EX8208 switches—Replace
EX8216 switches—Replace
view
show chassis environment fpc (M120 Router) on page 768
show chassis environment fpc (M160 Router) on page 769
show chassis environment fpc (M320 Router) on page 769
show chassis environment fpc (MX240 Router) on page 770
show chassis environment fpc (MX480 Router) on page 771
show chassis environment fpc (MX960 Router) on page 772
show chassis environment fpc (T Series Core Routers) on page 773
show chassis environment fpc lcc (TX Matrix Router) on page 773
show chassis environment fpc lcc (TX Matrix Plus Router) on page 774
Table 131 on page 767 lists the output fields for the
command. Output fields are listed in the approximate order in which they appear.
—FPC is not detected by the router.
Unknown
Empty
—No FPC is present.
—FPC is detected by the chassis daemon but is either not supported by the current version
Present
of the Junos OS, or the FPC is coming up but not yet online.
—FPC is in intermediate or transition state.
Ready
—Intermediate state during which the FPC is coming up but not yet online, and
Announce online
the chassis manager acknowledges the chassisd FPC online initiative.
—FPC is online and running.
Online
—FPC is powered down.
Offline
Diagnostics
—FPC is set to operate in diagnostics mode.
Chapter 42: Operational Mode Commands for System Monitoring
with a value from 0 through 7 (line card).
slot
slot
with a value from 0 through 15 (line card).
show chassis environment fpc
with 0.
slot
with a value
slot
767

Advertisement

Table of Contents
loading

Table of Contents