Reverting To The Rescue Configuration For The Ex Series Switch - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

Related
Documentation

Reverting to the Rescue Configuration for the EX Series Switch

Copyright © 2010, Juniper Networks, Inc.
NOTE: The
load factory default
switches configured in a Virtual Chassis with multiple members. In a
multimember Virtual Chassis configuration, you can revert to the default
factory configuration while retaining the Virtual Chassis parameters (member
ID, mastership priority, or settings of VCP uplinks) using the following
procedure:
[edit]
1.
user@switch# load factory default
[edit]
2.
user@switch# delete system commit factory-settings
[edit]
3.
user@switch# commit
Check the member ID and mastership priority with the
4.
command and check to see whether there are remaining settings
status
for uplink VCPs by using the
Configuring an EX4200 Virtual Chassis (CLI Procedure) on page 981
EX2200 Switch Default Configuration on page 385
EX3200 Default Configuration on page 389
EX4200 Default Configuration on page 393
EX4500 Default Configuration on page 397
EX8200 Switch Default Configuration on page 403
Understanding Configuration Files for EX Series Switches on page 381
For more information about load factory default, see theJunos OS CLI User Guide.
If someone inadvertently commits a configuration that denies management access to
an EX Series switch and the console port is not accessible, you can overwrite the invalid
configuration and replace it with the rescue configuration by using the LCD panel on the
switch. The rescue configuration is a previously committed, valid configuration.
You can also revert to the default factory configuration, as described in "Reverting to the
Default Factory Configuration for the EX Series Switch" on page 415.
Before you begin to revert to the rescue configuration:
Ensure that you have physical access to the switch.
A rescue configuration for the switch must have been previously set.
Chapter 19: Managing Junos OS Configuration
command by itself is not supported on EX4200
show virtual-chassis vc-port
show virtual-chassis
command.
417

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents