On a TX Matrix Plus router, power off all T1600 routers (or line-card chassis)
connected to the TX Matrix Plus router.
—(EX4200 switches only) (Optional) Power off all members of the Virtual
all-members
Chassis configuration.
at time
—(Optional) Time at which to power off the software, specified in one of the
following ways:
—Power off the software immediately. This is the default.
now
+minutes
—Number of minutes from now to power off the software.
—Absolute time at which to power off the software, specified as
yymmddhhmm
year, month, day, hour, and minute.
hh:mm
—Absolute time on the current day at which to power off the software.
—(Optional) Power off both Routing Engines at the same time.
both-routing-engines
in minutes
—(Optional) Number of minutes from now to power off the software. This
option is an alias for the
lcc number
—(Optional) (TX Matrix and TX Matrix Plus router only) On a TX Matrix router,
power off a T640 router that is connected to the TX Matrix router. On a TX Matrix
Plus router, power off a T1600 router that is connected to the TX Matrix Plus router.
Replace
with a value from
number
local
—(EX4200 switches only) (Optional) Power off the local Virtual Chassis member.
media (compact-flash | disk | removable-compact-flash | usb)
for next boot. (The options
routers only.)
—(EX Series switches only) (Optional) Power off the boot
media (external | internal)
media:
—Power off the external mass storage device.
external
internal
—Power off the internal flash device.
—(EX4200 switches only) (Optional) Power off the specified member
member member-id
of the Virtual Chassis configuration. Replace
9.
—(Optional) Message to display to all system users before powering off
message "text"
the software.
other-routing-engine
—(Optional) Power off the other Routing Engine from which the
command is issued. For example, if you issue the command from the master Routing
Engine, the backup Routing Engine is halted. Similarly, if you issue the command
from the backup Routing Engine, the master Routing Engine is halted.
option.
at +minutes
through
.
0
3
removable-compact-flash
member-id
Copyright © 2010, Juniper Networks, Inc.