Appendix A

Ribbon

Ribbon
Roll OD
Roll ID
Std Length
Max Length
Thickness

Electrical

Input Voltage
Power Entry Module
WARNING
The SLPA must be connected to a properly grounded receptacle free of
power surges and fluctuations. Proper operation/protection of the SLPA
can only be guaranteed if its power supply is maintained within the
electrical supply specifications given above.
The power supply cord used with the SLPA must be a 2 conductor plus
ground type with minimum 0.75 mm square conductors. This connector
must incorporate a standard IEC appliance coupler on one end and a
main plug on the other end, which is suitable for use and application of
the product and is approved for use in the country of application.

Pneumatic

Supply Pressure
Apply Cylinder Pressure
Air Flow Rates
Connection
322
3.0 inches
1.0 inches
1476 feet
2050 feet
4.5 micron
±
115 VAC
10%, single phase @ 50 to 60 Hz
±
230 VAC
10%, single phase @ 50 to 60 Hz
One 2.0 Amp, 250 V Slo-Blo fuse
Recommended setting for regulated air
supply is 80 to 100 psi (550 to 690 kPa)
Recommended setting for internal apply
pressure is 30 to 40 psi (140 to 275 kPA)
3 to 5 scfm (85 to 142 sclm)
1/4 inch NPT
76 mm
25.4 mm
450 meters
625 meters
4.5 micron