Printronix SLPA7000 User Manual page 151

Smart label printer applicator
Hide thumbs Also See for SLPA7000:
Table of Contents

Advertisement

Mode 5. Normally high. When the label has been printed completely, a
low going, 50 millisecond pulse is sent. (This mode shows the end of a
label print cycle, even in batch mode where labels are continuously being
printed.)
Mode 6. Identical to Mode 5, except normally low with a high going 50
millisecond pulse.
Mode 7. Normally high. At the beginning of a label being printed, the
output is set low. When the label is completed, the signal goes high. If
another label has started printing, the signal stays high for 50
milliseconds. (This mode shows start and end of a label print cycle, even
in batch mode where labels are continuously printed.)
Mode 8. Identical to Mode 7, except normally low with high going signal.
GPIO Ctrl Status
NOTE: This menu appears only if an internal table is selected or if there is no
user-defined table.
Programmable via printer menu.
Data Ready. The default. Low when sufficient data has been received to
begin printing the next label. High whenever printing is stopped after the
current label due to any condition causing the printer to pause or in the
absence of a label format.
Offline. Low whenever the printer is offline. High whenever the printer is
able to receive command streams and print labels.
GPIO Monitor
NOTE: This menu appears only if a user-defined table is downloaded to the
printer and selected.
Shows the status of the GPIO inputs on the LCD.
Input OFF. The default. Disable.
Input ON. Enable.
GPIO Print&Apply
NOTE: This menu appears only if Admin User is set to Enable (in the
PRINTER CONTROL menu).
Enables the use of print and apply hardware.
Disable. The default.
Enable.
GPIO CONTROL Submenus
151

Advertisement

Table of Contents
loading

Table of Contents