Table 17 Input codes 94
Code
Displayed Name
Description
94-105 Cleaning unit home
IME cleaning unit home sensor
sensor
Output Codes
Table 18 Output codes 05
Code
Displayed Name Description
05-062 DADH feed clutch DADH feed clutch (CL05-062)
05-074 DADH feed motor DADH feed motor (MOT05-074)
05-098 DADH nudger
DADH nudger motor (MOT05-098) On/off. 10 seconds time out
motor
05-099 DADH CVT motor DADH CVT stepper motor
(MOT05-099)
05-100 DADH duplex
DADH duplex/exit solenoid
solenoid
(SOL05-101)
05-101 DADH Active Hot-
DADH Active Hotline. Required to
line
keep alive until DADH Hotline
Detect sensor can be run.
Table 19 Output codes 10
Code
Displayed Name
Description
10-018 Post Transfix
Post transfix motor M4 (MOT10-
motor (M4)
018)
10-019 Front Transfix
Front Transfix Motor (MOT10-019) On/off.
Motor
10-020 Rear Transfix
Rear Transfix Motor (MOT10-020) On/off.
Motor
10-021 Stripper Solenoid
Stripper Solenoid (SOL10-021)
10-022 Stripper Jam
Stripper Jam Clearance LED
Clearance LED
10-023 Strip Gate Latch
Strip Gate Latch
10-024 Transfix Front and
Transfix Front and Back
Back
10-025 Strip Gate Unlatch Strip Gate Unlatch
General Procedures/Information
dC330
General
Code
High/low
12-045 SU1 motor backward
General
On/off. Normally linked with
12-056 SetCamp SolenoidOn
feed motor. 30 seconds time-
out.
12-059 Elevator motor up
On/off. 90 seconds timeout
12-060 Elevator motor down
On/off. 90 seconds timeout
On/off. 90 seconds timeout
12-223 Transport Motor 1
High = Active. 90 seconds
time out
12-224 Transport Motor 2
12-225 Exit Diverter Solenoid
General
12-226 Front Tamper Motor
On/off.
12-227 Rear Tamper Motor
12-228 Front Tamper Motor
On/off.
12-229 Rear Tamper Motor
On/off.
12-230 Tampers to A4LEF
On/off.
On/off.
12-231 Tampers to 8.5x11LEF Move the LCSS tampers to 8.5"x11"
On/off.
12-232 Tamper Motor Cycle
February 2013
6-270
Table 20 Output codes 12
Displayed Name
Description
HVF/LCSS Staple unit 1 motor reverse
(MOT12-045)
CAUTION
Do not run the following codes
together: 12-045, 12-233, 12-236, 12-
242, 12-244, 12-249, 12-250. Run-
ning these codes at the same time can
cause damage to the machine.
HVF SetClamp SolenoidOn (SOL12-
056)
HVF/LCSS Elevator motor up
HVF/LCSS Elevator motor down
Runs the LCSS transport Motor 1, and
HVF transport motor 1A and Transport
motor 1B (MOT12-223)
Runs the LCSS, and HVF transport
motor 2 (MOT12-224)
Runs the LCSS, HVF exit diverter gate
solenoid and HVF BM upper diverter
solenoid (SOL12-225)
Runs the LCSS and HVF front tamper
Home
motor (MOT12-227) to the home posi-
tion.
Runs the LCSS and HVF rear tamper
Home
motor (MOT12-228) to home position
Runs the LCSS and HVF front tamper
Move
motor (MOT12-226) move inbound.
Runs the LCSS and HVF rear tamper
Move
motor (MOT12-227) move inbound.
Moves the LCSS tampers to A4LEF
position.
LEF position.
Cycles the LCSS tampers in and out
until time-out or stop.
General
On/off. 110 millisec-
onds time out.
On/off. 100 millisec-
onds time out.
On/off.
500miliseconds tim-
eout.
On/off.
500miliseconds tim-
eout.
On/off. 90 seconds
time out
On/off. 90 seconds
time out
On/off. 5 seconds
time out
On/off. 5 seconds
time-out
On/off. 5 seconds
time out
On/off. 5 seconds
time out
On/off. 5 seconds
time out
On/off. 5 seconds
time out
On/off. 5 seconds
time out
On/off. 90 seconds
time out