GD310-UL series VFD
Function
Name
code
the input
terminals
ON-OFF filter
P05.11
time
Virtual
P05.12
terminals
setting
Terminals
P05.13
control running
mode
Set the bit to 0, the input terminal is anode.
Set the bit to 1, the input terminal is cathode.
BIT0
BIT1
S1
S2
BIT5
BIT6
S6
S7
The setting range: 0x000–0x1FF
Set the sample filter time of S1–S8 and HDI
terminals. If the interference is strong, increase the
parameter to avoid the disoperation.
0.000–1.000s
0x000–0x1FF (0: Disabled, 1: Enabled )
BIT0: S1 virtual terminal
BIT1: S2 virtual terminal
BIT2: S3 virtual terminal
BIT3: S4 virtual terminal
BIT4: S5 virtual terminal
BIT5: S6 virtual terminal
BIT6: S7 virtual terminal
BIT7: S8 virtual terminal
BIT8: HDI virtual terminal
Set the operation mode of the terminals control
0: 2-wire control 1, comply the enable with the
direction. This mode is widely used. It determines the
rotation direction by the defined FWD and REV
terminals command.
FWD
K1
REV
K2
COM
1: 2-wire control 2; Separate the enable from the
direction. FWD defined by this mode is the enabling
ones. The direction depends on the state of the
defined REV.
Description
BIT2
BIT3
S3
S4
BIT7
BIT8
S8
HDI
Running
FWD
REV
command
OFF
OFF
ON
OFF
running
OFF
ON
ON
ON
-65-
Function parameter
Default
value
BIT4
S5
0.010s
0x000
Stop
0
FWD
REV
running
Hold
Modify
○
◎
◎
Need help?
Do you have a question about the Goodrive 310-UL Series and is the answer not in the manual?
Questions and answers