GD310-UL series VFD
Function
Name
code
coefficient
Correction
P02.28
coefficient of
motor 1 power
Parameter
P02.29
display of
motor 1
P03 Group Vector control
Function
Name
code
Speed loop
P03.00
proportional
gain1
Speed loop
P03.01
integral time1
Low switching
P03.02
frequency
Speed loop
P03.03
proportional
gain 2
Speed loop
P03.04
integral time 2
High switching
P03.05
frequency
coefficient.
So, the bigger the value of K is, the smaller the value
of M is. When M =116%, the fault will be reported
after 1 hour, when M =200%, the fault will be
reported after 1 minute, when M>=400%, the fault
will be reported instantly.
1 hour
1 minute
Setting range: 20.0%–120.0%
Correct the power displaying of motor 1.
Only impact the displaying value other than the
control performance of the VFD.
Setting range: 0.00–3.00
0: Display according to the motor type
1: Display all
The parameters P03.00–P03.05 only apply to vector
control mode. Below the switching frequency
1(P03.02), the speed loop PI parameters are: P03.00
and
P03.01.
Above
2(P03.05), the speed loop PI parameters are: P03.03
and P03.04. PI parameters are gained according to
the linear change of two groups of parameters. It is
shown as below:
PI parameter
P03.00, P03.01
P03.02
Description
Times of motor overload
200%
116%
Description
the
switching
P03.03, P03.04
Output frequency
P03.05
-54-
Function parameter
Default
value
1.00
0
Default
value
20.0
frequency
0.200s
5.00Hz
20.0
0.200s
10.00Hz
Modify
●
●
Modify
○
○
○
○
○
○