P13––Control parameters of synchronous motor
Function
Name
code
Reduction rate of
the pull-in current
P13.00
of synchronous
motor
Description
protection is performed after motor overload lasts
for 12 minutes; when M=180%, protection is
performed after motor overload lasts for 5 minutes;
when M=200%, protection is performed after
motor overload lasts for 60 seconds; and when M≥
400%, protection is performed immediately.
Time (min)
60
12
5
1
116%
Setting range: 20.0%–120.0%
0.00–3.00
0: Display based on the motor type; under this
mode, only parameters related to current motor
type will be displayed.
1: Display all; under this mode, all the parameters
will be displayed.
2
0–30.000kgm
/
Description
This parameter is used to set the reduction rate of
the input reactive current. When the active current
of the synchronous motor increases to some
extent, the input reactive current can be reduced to
improve the power factor of the motor.
Setting range: 0.0%–100.0% (of the motor rated
-212-
Current overload
multiple
150% 180%
200%
Function parameter list
Default
Modify
value
1.00
0
0.000
2
kgm
/
/
Default
Modify
value
80.0%