Setting
Output current (relative to
4
Output current (relative to
5
6
7
8
Set torque value (bipolar)
Output torque (absolute
9
10
11
12
13
High-speed pulse HDIA input 0.00–50.00kHz
Value 1 set through
14
Modbus/Modbus TCP
Value 2 set through
15
Modbus/Modbus TCP
Value 1 set through
16
PROFIBUS/CANopen/Device
Net communication
Value 2 set through
17
PROFIBUS/CANopen/Device
Net communication
Value 1 set through Ethernet
18
Value 2 set through Ethernet
19
20
High-speed pulse HDIB input 0.00–50.00kHz
Value 1 set through
21
EtherCAT/PROFINET/
EtherNET IP communication
22
Torque current (bipolar)
23
Function
VFD)
motor)
Output voltage
Output power
value)
AI1 input value
AI2 input value
AI3 input value
communication
communication
communication
communication
Exciting current
0–Twice the VFD rated current
0–Twice the motor rated current
0–1.5 times the VFD rated voltage
0–Twice the motor rated power
0–Twice the motor rated current. A negative value
corresponds to 0.0% by default.
0 – +/-(Twice the motor rated torque)
0–10V/0–20mA
0V–10V. A negative value corresponds to 0.0% by
default.
0–10V/0–20mA
0–1000
0–1000
0–1000
0–1000
0–1000
0–1000
0–1000. A negative value corresponds to 0.0% by
default.
0–Triple the motor rated current. A negative value
corresponds to 0.0% by default.
0–Triple the motor rated current. A negative value