Goodrive350 series high-performance multifunction VFD
Note: This kind of V/F curve separation can be applied in various frequency-conversion power
sources, however, you should be cautious of parameter setup as improper setup may damage the
machine.
Function
code
P00.00
Speed control mode
P00.03 Max. output frequency P00.04–400.00Hz
Upper limit of running
P00.04
frequency
Lower limit of running
P00.05
frequency
P00.11
Acceleration time 1 0.0–3600.0s
P00.12
Deceleration time 1 0.0–3600.0s
P02.00
Type of motor 1
Rated power of
P02.02
asynchronous motor 1
Rated voltage of
P02.04
asynchronous motor 1
V/F curve setting of
P04.00
motor 1
Torque boost of motor
P04.01
Motor 1 torque boost
P04.02
V/F frequency point 1
P04.03
of motor 1
P04.04
V/F voltage point 1 of 0.0%–110.0%
Name
0: Sensorless vector control (SVC) mode 0
1: SVC 1
2: SVPWM
3: FVC
Note: To select 0, 1, or 3 as the control mode,
enable the VFD to perform motor parameter
autotuning first
P00.05–P00.03
0.00Hz–P00.04
0: Asynchronous motor
1: Synchronous motor
0.01Hz–P00.03 (Max. output frequency)
0–1200V
0: Straight-type V/F curve
1: Multi-point V/F curve
2: Torque-down V/F curve (power of 1.3)
3: Torque-down V/F curve (power of 1.7)
4: Torque-down V/F curve (power of 2.0)
5: Customized V/F (V/F separation)
0.0%: (automatic) 0.1%–10.0%
1
0.0%–50.0% (rated frequency of motor 1)
cut-off
0.00Hz–P04.05
Description
-63-
Basic operation guidelines
Default
value
2
50.00Hz
50.00Hz
0.00Hz
Depends
on model
Depends
on model
0
50.00Hz
Depends
on model
0
0.0%
20.0%
0.00Hz
0.0%