Goodrive350 series high-performance multifunction VFD
Function
Name
code
STOP/RST key situation.
P07.05–
Reserved
P07.07
Frequency
P07.08
display
coefficient
Speed display
P07.09
coefficient
Linear speed
P07.10
display
coefficient
Temperature of
P07.11
rectifier bridge
module
Temperature of
P07.12
inverter module
Software version
P07.13
of control board
Accumulated
P07.14
running time
High bit of VFD
P07.15
power
consumption
Low bit of VFD
P07.16
power
consumption
P07.17
Reserved
Rated power of
P07.18
VFD
Rated voltage of
P07.19
VFD
P07.20
Rated current of 0.1–6000.0A
Description
0: valid only for panel control only
1: valid for both panel and terminal control
2: valid for both panel and communication control
3: valid for all control modes
/
0.01–10.00
Display frequency=running frequency× P07.08
0.1–999.9%
Mechanical speed=120×display running
frequency×P07.09/number of motor pole pairs
0.1–999.9%
Linear speed=mechanical speed×P07.10
-20.0–120.0° C
-20.0–120.0° C
1.00–655.35
0–65535h
Display the power consumption of the VFD.
VFD power consumption=P07.15×1000+P07.16
Setting range of P07.15: 0–65535 kWh (×1000)
Setting range of P07.16: 0.0–999.9 kWh
/
0.4–3000.0kW
50–1200V
-181-
Function parameter list
Default
Modify
value
/
/
○
1.00
○
100.0%
○
1.0%
●
0.0° C
●
0.0° C
Depends
●
on
version
●
0h
●
0kWh
●
0.0kWh
/
/
Depends
●
on model
Depends
●
on model
●
Depends
Need help?
Do you have a question about the Goodrive350 Series and is the answer not in the manual?