Goodrive350 series high-performance multifunction VFD
Function
Name
code
Relay RO9
P26.10
output selection
Relay RO10
P26.11
output selection
Output terminal
P26.12
polarity of
expansion card
HDO2 switch-on
P26.13
delay
HDO2 switch-off
P26.14
delay
Y2 switch-on
P26.15
delay
Y2 switch-off
P26.16
delay
Y3 switch-on
P26.17
delay
Y3 switch-off
P26.18
delay
Relay RO3
P26.19
switch-on delay
Relay RO3
P26.20
switch-off delay
Relay RO4
P26.21
switch-on delay
Relay RO4
P26.22
switch-off delay
Description
0x0000–0x1FFF
Bit0: Y2
Bit1: Y3
Bit2: HDO2
Bit3: RO3
Bit4: RO4
Bit5: RO5
Bit6: RO6
Bit7: RO7
Bit8: RO8
Bit9: RO9
Bit10: RO10
Bit11: RO11
Bit12: RO12
Used to define the corresponding delay of the level
variation from switch-on to switch-off.
Y electric level
Invalid
Y valid
Switch on
delay
Setting range: 0.000–50.000s
Note: P26.13 and P26.14 are valid only when
P26.00 is set to 1.
-260-
Function parameter list
invalid
Valid
Switch off
delay
Default
Modify
value
○
0
○
0
○
0x0000
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s
○
0.000s