Goodrive350 series high-performance multifunction VFD
Function
code
Function parameter
P00.18
P02.00
Type of motor 1
Rated power of
P02.01
asynchronous motor 1
Rated frequency of
P02.02
asynchronous motor 1
Rated speed of
P02.03
asynchronous motor 1
Rated voltage of
P02.04
asynchronous motor 1
Rated current of
P02.05
asynchronous motor 1
Name
3: Static autotuning 2 (partial autotuning) ;
when current motor is motor 1, only P02.06,
P02.07 and P02.08 will be autotuned; when
current motor is motor 2, only P12.06,
P12.07 and P12.08 will be autotuned.
4: Rotary autotuning 2, which is similar to
rotary autotuning 1 but is only applicable to
asynchronous motors.
5: Rotary autotuning 3 (partial autotuning),
which is only applicable to asynchronous
motors.
0: No operation
1: Restore default values (excluding motor
parameters)
2: Clear fault records
3: Reserved
4: Reserved
5: Restore default values (for factory test
mode)
restoration
6: Restore default values (including motor
parameters)
Note: After the selected operation is done,
this parameter is automatically restored to 0.
Restoring the default values may delete the
user password. Exercise caution when using
this function. The option 5 can be used only
for factory testing.
0: Asynchronous motor
1: Synchronous motor
0.1–3000.0kW
0.01Hz–P00.03 (Max. output frequency)
1–60000rpm
0–1200V
0.8–6000.0A
Description
-53-
Basic operation guidelines
Default
value
0
0
Depends
on model
50.00Hz
Depends
on model
Depends
on model
Depends
on model
Need help?
Do you have a question about the Goodrive350 Series and is the answer not in the manual?
Questions and answers