Goodrive350 series high-performance multifunction VFD
Function
Name
code
terminal control
setup
UP terminal
frequency
P08.45
incremental
integral rate
DOWN terminal
frequency
P08.46
decremental
change rate
Action selection
for frequency
P08.47
setup during
power down
High bit of initial
P08.48
value of power
consumption
Description
Ones: Frequency control selection
0: UP/DOWN terminal setup is valid
1: UP/DOWN terminal setup is invalid
Tens: Frequency control selection
0: Valid only when P00.06=0 or P00.07=0
1: All frequency modes are valid
2: Invalid for multi-step speed when multi-step
speed takes priority
Hundreds: Action selection during stop
0: Valid
1: Valid during running, clear after stop
2: Valid during running, clear after receiving stop
command
0.01–50.00Hz/s
0.01–50.00Hz/s
0x000–0x111
Ones place: Action selection at power-off during
frequency adjusting through digitals.
0: Save the setting at power-off.
1: Clear the setting at power-off.
Action selection at power-off during frequency
adjusting through Modbus/Modbus TCP
communication
0: Save the setting at power-off.
1: Clear the setting at power-off.
Hundreds place: Action selection at power-off
during frequency adjusting through DP
communication
0: Save the setting at power-off.
1: Clear the setting at power-off.
Set the initial value of power consumption.
Initial value of power consumption=P08.48×1000+
P08.49
-191-
Function parameter list
Default
Modify
value
○
0.50Hz/s
○
0.50Hz/s
○
0x000
○
0kWh