Goodrive350 series high-performance multifunction VFD
Function
Name
code
P06.07 Y switch-off delay delay of the level variation from switch-on to
HDO switch-on
P06.08
delay
HDO switch-off
P06.09
delay
Relay RO1
P06.10
switch-on delay
Relay RO1
P06.11
switch-off delay
Relay RO2
P06.12
switch-on delay
Relay RO2
P06.13
switch-off delay
AO1 output
P06.14
selection
P06.15
Reserved
HDO high-speed
P06.16
pulse output
Description
switch-off.
Y electric level
Invalid
Y valid
Switch on
delay
Setting range: 0.000–50.000s
Note: P06.08 and P06.09 are valid only when
P06.00=1.
0: Running frequency
1: Set frequency
2: Ramp reference frequency
3: Rotational speed (100% corresponds to the
speed corresponding to max. output frequency)
4: Output current (100% corresponds to twice the
VFD rated current)
5: Output current (100% corresponds to twice the
motor rated current)
6: Output voltage (100% corresponds to 1.5 times
the VFD rated voltage)
7: Output power (100% corresponds to twice the
motor rated power)
8: Set torque (100% corresponds to twice the
motor rated torque)
9: Output torque (Absolute value, 100%
corresponds to twice the motor rated torque)
10: AI1 input
11: AI2 input
12: AI3 input
13: HDIA input
14: Value 1 set through Modbus/Modbus TCP
communication
15: Value 2 set through Modbus/Modbus TCP
communication
-177-
Function parameter list
invalid
Valid
Switch off
delay
Default
Modify
value
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0
/
/
0