Goodrive350 series high-performance multifunction VFD
Function
Name
code
Integral
coefficient in IF
P04.43
mode for
asynchronous
motor 1
Starting
frequency point
for switching off
P04.44
IF mode for
asynchronous
motor 1
Enable/disable IF
mode for
P04.45
asynchronous
motor 2
Current setting in
IF mode for
P04.46
asynchronous
motor 2
Proportional
coefficient in IF
P04.47
mode for
asynchronous
motor 2
Integral
coefficient in IF
P04.48
mode for
asynchronous
motor 2
Starting
frequency point
for switching off
P04.49
IF mode for
asynchronous
motor 2
End frequency
P04.50
point for
switching off IF
Description
When IF control is adopted for asynchronous
motor 1, this parameter is used to set the integral
coefficient of the output current closed-loop
control.
Setting range: 0–5000
0.00Hz–P04.50
0: Disable
1: Enable
When IF control is adopted for asynchronous
motor 2, this parameter is used to set the output
current. The value is a percentage in relative to the
rated current of the motor.
Setting range: 0.0–200.0%
When IF control is adopted for asynchronous
motor 2, this parameter is used to set the
proportional coefficient of the output current
closed-loop control.
Setting range: 0–5000
When IF control is adopted for asynchronous
motor 2, this parameter is used to set the integral
coefficient of the output current closed-loop
control.
Setting range: 0–5000
0.00Hz–P04.51
P04.44–P00.03
-165-
Function parameter list
Default
Modify
value
○
350
○
10.00Hz
◎
0
○
120.0%
○
650
○
350
○
10.00Hz
○
25.00Hz