Goodrive350 series high-performance multifunction VFD
Function
Name
code
setting of lower
limit of AI2
Intermediate
P05.31
value 1 of AI2
Corresponding
setting of
P05.32
intermediate
value 1 of AI2
Intermediate
P05.33
value 2 of AI2
Corresponding
setting of
P05.34
intermediate
value 2 of AI2
Upper limit value
P05.35
of AI2
Corresponding
P05.36
setting of upper
limit of AI2
Input filter time of
P05.37
AI2
HDIA high-speed
P05.38
pulse input
function
Lower limit
P05.39
frequency of
HDIA
Description
100%
-10V
AI2
Input filter time: Adjust the sensitivity of analog
input, increase this value properly can enhance
the anti-interference capacity of analog variables;
however, it will also degrade the sensitivity of
analog input.
Note: AI1 can support 0–10V/0–20mA input, when
AI1 selects 0–20mA input; the corresponding
voltage of 20mA is 10V; AI2 supports -10V–+10V
input.
Setting range of P05.24: 0.00V–P05.26
Setting range of P05.25: -300.0%–300.0%
Setting range of P05.26: P05.24–10.00V
Setting range of P05.27: -300.0%–300.0%
Setting range of P05.28: 0.000s–10.000s
Setting range of P05.29: -10.00V–P05.31
Setting range of P05.30: -300.0%–300.0%
Setting range of P05.31: P05.29–P05.33
Setting range of P05.32: -300.0%–300.0%
Setting range of P05.33: P05.31–P05.35
Setting range of P05.34: -300.0%–300.0%
Setting range of P05.35: P05.33–10.00V
Setting range of P05.36: -300.0%–300.0%
Setting range of P05.37: 0.000s–10.000s
0: Set input via frequency
1: Reserved
2: Input via encoder, used in combination with
HDIB
0.000 kHz – P05.41
-173-
Corresponding setting
AI
0
10V
20mA
AI1
-100%
Function parameter list
Default
Modify
value
○
0.00V
○
0.0%
○
0.00V
○
0.0%
○
10.00V
○
100.0%
○
0.030s
◎
0
0.000
○
kHz
Need help?
Do you have a question about the Goodrive350 Series and is the answer not in the manual?
Questions and answers