Goodrive350 series high-performance multifunction VFD
synchronous motor 1) can be obtained via calculation.
4. Motor autotuning can be carried out on current motor only, if you need to perform autotuning on
the other motor, switch over the motor through selecting the switchover channel of motor 1 and
motor 2 by setting the ones of P08.31.
Related parameter list:
Function
code
Channel of running
P00.01
P00.15
Motor parameter autotuning
P02.00
P02.01
asynchronous motor 1
Rated frequency of
P02.02
asynchronous motor 1
P02.03
asynchronous motor 1
Name
commands
Type of motor 1
Rated power of
Rated speed of
Description
0: Keypad
1: Terminal
2: Communication
0: No operation
1: Rotary autotuning 1; carry out
comprehensive motor parameter
autotuning; rotary autotuning is used in
cases where high control precision is
required;
2: Static autotuning 1 (comprehensive
autotuning); static autotuning 1 is used in
cases where the motor cannot be
disconnected from load;
3: Static autotuning 2 (partial
autotuning) ; when current motor is motor
1, only P02.06, P02.07 and P02.08 will
be autotuned; when current motor is
motor 2, only P12.06, P12.07 and P12.08
will be autotuned.
4: Rotary autotuning 2, which is similar to
rotary autotuning 1 but is only applicable
to asynchronous motors.
5: Rotary autotuning 3 (partial
autotuning), which is only applicable to
asynchronous motors.
0: Asynchronous motor
1: Synchronous motor
0.1–3000.0kW
0.01Hz–P00.03 (Max. output frequency)
1–60000rpm
-75-
Basic operation guidelines
Default
value
0
0
0
Depends
on model
50.00Hz
Depends
on model