ABB IRB 6650S Product Manual page 324

Hide thumbs Also See for IRB 6650S:
Table of Contents

Advertisement

4 Repair
4.6.5 Replacement of motor, axis 5
Continued
Removal, motor, axis 5
The procedure below details how to remove motor, axis 5.
1
2
3
4
5
6
7
8
Continues on next page
324
Action
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Drain the oil from gearbox axis 5.
Remove the wrist unit.
Place the wrist unit safely on a workbench, in a
fixture or similar.
Remove the cover on top of the motor by unscrew-
ing its four attachment screws.
Remove the cable gland cover at the cable exit
by unscrewing its two attachment screws.
Disconnect all connectors beneath the motor
cover and remove the separate cable of the axis-
5 motor.
© Copyright 2004-2022 ABB. All rights reserved.
Note
Note
Detailed in the section
axis-5 gearbox on page
Detailed in the section
wrist unit on page
243.
xx1400002580
Product manual - IRB 6650S
3HAC020993-001 Revision: AG
Changing oil,
165.