4 Repair
4.4.1 Replacing the turning disk
Continued
Removing, turning disk
Use this procedure to remove the turning disk.
1
2
3
4
5
6
7
Continues on next page
238
Action
Run the robot to a position where the oil plug, drain-
ing of axis 6 gearbox faces downwards.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
Remove any equipment fitted to the turning disk.
Drain the axis 6 gearbox.
Remove the attachment screws that secure the
turning disk.
Remove the turning disk.
Foundry Plus:
Remove old flange sealant residues and other con-
tamination from the contact surfaces.
© Copyright 2004-2022 ABB. All rights reserved.
Note
Shown in the figure
Location of
turning disk on page
237.
See section
Changing oil, axis-6 gear-
box on page 168