ABB IRB 6650S Product Manual page 211

Hide thumbs Also See for IRB 6650S:
Table of Contents

Advertisement

2
3
4
5
6
7
Product manual - IRB 6650S
3HAC020993-001 Revision: AG
Action
Refit the cable gland securing the cables in
the armhouse.
Note
The cable harness is delivered pretwisted.
Make sure not to affect this by twisting the
cable harness further in any direction.
Reconnect all connectors on motors axes 3
and 4.
Secure the cable harness to the upper arm-
house by refitting the velcro strap to the cable
bracket at the upper armhouse.
Refit the velcro strap at the guide plate axis 2.
Gently insert the cable harness from the rear
into the upper arm.
Connect the two connectors inside the upper
arm tube, R2.FB5 and R3.MP5 and secure the
cable bracket with its two attachment screws
to the tube.
Note
The position of axis 6 must be +90° for a cor-
rect installation of the cable harness.
© Copyright 2004-2022 ABB. All rights reserved.
4.3.1 Replacing cable harness, axes 1-6
Note
xx0100000143
Shown in the figure
harness on page
198.
Shown in the figure
the upper arm on page
Continues on next page
4 Repair
Continued
Location of cable
Cable brackets of
200.