No.
Items
3280 SP080
3281 SP081 LMCA
Fixed control
constant
3282 SP082 LMCB
3283 SP083
3284
SP084
to
to
3286
SP086
3287
SP087 DIQM
Target value of
(PR)
variable torque
limit magnifica-
tion at
deceleration
3288
SP088 DIQN
Speed for starting
(PR)
change of
variable torque
limit magnifica-
tion at
deceleration
3289 SP089
3290 SP090
3291 SP091 OFSN Motor PLG
forward rotation
offset compensa-
tion
3292 SP092 OFSI
Motor PLG
reverse rotation
offset compensa-
tion
3293
SP093 ORE
Tolerable pulse
(PR)
check error
3294
SP094 LMAV Load meter
(PR)
output filter
3295
SP095 VFAV
Fixed control
(PR)
constant
8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Use not possible.
This is used by Mitsubishi.
Set to "0" unless particularly designated.
Use not possible.
Set the minimum value of variable torque
limit at deceleration.
Set the speed where the torque limit value at
deceleration starts to change.
Torque limit
100%
SP087
SP088
Use not possible.
Use not possible.
Set the PLG offset value for the forward
rotation.
Normally set to "0".
Set the PLG offset value for the reverse
rotation.
Normally set to "0".
Set this when detecting the pulse detector's
pulse mistakes.
(Valid only for full close control.)
Set the filter time constant of load meter
output.
When "0" is set, a filter time constant is set to
100ms.
Set by Mitsubishi.
Set "0" unless designated in particular.
II - 250
Details
Inversely proportional
to speed
SP017
Setting
Standard
range
setting
0
0
0
0
0
0
0 to 150
75
(%)
0 to 32767
3000
(r/min)
0
0
0
0
-2048 to
0
2047
(-1mv)
-2048 to
0
2047
(-1mv)
0 to 32767 0
0 to 32767
0
(2ms)
0
0