Items
set11
Door interlock
(bit5)
spindle speed
clamp valid
set11
External
(bit6)
deceleration
axis compliance
valid
set11
APLC software
(bit7)
working
environment
setting
1240
set12
Handle input
(PR)
(bit0)
pulse
set12
Megatorque
(bit1)
motor handle
feed
magnification
set12
Zero point shift
(bit2)
amount
magnification
5. Base Specifications Parameters
Details
Select whether to validate the spindle clamp speed
changeover function by the PLC signal.
0: Invalid
1: Valid
Designate the method for setting the external
deceleration speed.
0: Set speed common for all axes (#1216 extdcc
external deceleration speed)
1: Set speed for each axis (#2086 exdcax
external deceleration speed)
0: Run the APLC software with the ROM.
1: Run the APLC software with the RAM.
Select the handle input pulse.
0: MELDAS standard handle pulse
1: Handle 400 pulse
Select the magnification of megatorque motor
handle 1 pulse.
0: Double the handle 1 pulse magnification
specified by the handle feed magnification
signal (Y2C0 to Y2C2).
1: Use the handle 1 pulse magnification
specified by the handle feed magnification
signal (Y2C0 to Y2C2) as is.
If "1" is set, the following magnification will be
applied on the #2027 G28sft reference point shift
amount, #2057 zero point proximity + and #2058
zero point proximity – settings.
μ
For 0.1
m
: 10-fold
μ
For 0.01
m : 100-fold
II - 69
Setting range (unit)
0/1
0/1
0/1
0/1
0/1
0/1