Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 169

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

#
Items
ext08
Tap cycle
(bit4)
selection
ext08
Deep hole tap
(bit5)
cycle override
selection
ext08
Switch corner
(bit6)
chamfering/
corner R
command
format
ext08
Return position
(bit7)
after macro
interrupt in fixed
cycle selection
1273
ext09
Switch ASIN
(PR)
(bit0)
calculation
results range
ext09
Switch system
(bit1)
variable unit
ext09
Switch G71,
(bit2)
G72, G73
cutting direction
judgment
ext09
Facing turret
(bit3)
mirror image
coordinate value
type
ext09
Facing turret
(bit4)
mirror image
valid axis
selection
5. Base Specifications Parameters
Details
Select the tap cycle.
0: Pecking tap cycle
1: Deep hole tap cycle
Select whether to validate override on the pulling
operation during synchronized tapping with the
deep hole tap cycle.
0: Invalid
1: Valid
The corner chamfering/corner R command format is
extended.
0: Command format I (conventional format)
Issue a command with comma (,C and ,R).
1: Command format II
In addition to command format I, commands
can be issued with an address that does not
have a comma.
Corner chamfering: I/K or C, corner R: R
Select the destination to return to after a macro
interrupt in the fixed cycle.
0: Return to block in fixed cycle.
1: Return to block after fixed cycle.
Select the ASIN calculation results range.
0: –90° to 90°
1: 90° to 270°
Select the unit for the system variable #3002 (time
during automatic start).
0: 1ms unit
1: 1 hour unit
Select whether to determine the cutting direction
with the finished shape, or according to the
commanded finishing allowance and cutting
allowance when the longitudinal rough cutting cycle
(G71), face rough cutting cycle (G72) or closed loop
cutting cycle (G73) is commanded.
0: Conventional specifications
Determined according to the finished shape
program.
1: Extended specifications
Determined according to the finishing
allowance and cutting allowance
commanded in the program.
Select the coordinate values of the axis for which
facing turret mirror image is valid.
0: Move axis in same direction as machine
value.
1: Move axis in direction opposite machine
value.
Select the axis for which facing turret mirror image
is valid.
0: Fixed to 1st axis.
1: Determined according to plane selected
when facing turret mirror image is
commanded.
II - 73
Setting range (unit)
0/1
0/1
0/1
0/1
0/1
0/1
0/1
0/1
0/1

Advertisement