No.
Items
3236
SP036 SFNC4 Spindle
(PR)
3237
SP037 SFNC5 Spindle
(PR)
8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Set the spindle function 4 in bit units.
function 4
F
E
7
6
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0
plg1
PLG of motor 1 valid
1
plg2
PLG of motor 2 valid
2
mag1 MAG of motor 1 valid
3
mag2 MAG of motor 2 valid
4
enc1
ENC of motor 1 valid
5
enc2
ENC of motor 2 valid
6
7
dssm Speedometer output
8
valid
9
dslm
Load meter output valid
A
B
C
D
E
F
Set the spindle function 5 in bit units.
function 5
F
E
splg dplg
7
6
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
enco
0
mago Magnetic sensor
1
2
plgo
3
4
5
6
7
nosg
8
9
nsno
A
noplg
B
C
D
E
dplg
F
splg
(Note) For bit0 to 2, do not set two bits or more to
"1" at the same time.
Details
D
C
B
A
5
4
3
2
enc2 enc1 mag2 mag1 plg2 plg1
PLG of motor 1 invalid
PLG of motor 2 invalid
MAG of motor 1 invalid
MAG of motor 2 invalid
ENC of motor 1 invalid
ENC of motor 2 invalid
Speedometer output
invalid
Load meter output
invalid
D
C
B
A
noplg nsno nosg
5
4
3
2
plgo mago enco
Encoder orientation
Encoder orientation
invalid
valid
Magnetic sensor
orientation invalid
orientation valid
PLG orientation invalid
PLG orientation valid
No-signal detection type
Monitoring only in
(Always monitoring)
position loop or
orientation-mode
No-signal detection
No-signal detection
valid
invalid
Constant monitor of
Constant monitor of
PLG-Z phase no-signal
PLG-Z phase no-signal
invalid
valid
This is used by Mitsubishi.
Set to "0" unless particularly designated.
II - 241
Setting
range
0000 to
FFFF
9
8
HEX
dslm dssm
setting
1
0
0000 to
FFFF
9
8
HEX
setting
1
0
Standard
setting
0000
0000