13. Auxiliary Axis Parameter
Turn the NC power OFF after setting parameters indicated with a (PR) in the table. The setting will be
validated after the power is turned ON again.
No.
Name
1
MSR
Motor series
(PR)
2
RTY
Regeneration
(PR)
option type
3
PC1
Motor side
(PR)
gear ratio
(machine
rotation ratio)
4
PC2
Machine side
(PR)
gear ratio
(motor rotation
ratio)
5
PIT
Feed pitch
(PR)
6
INP
In-position
detection width
13. Auxiliary Axis Parameter
Details
Set the motor series. This is automatically judged
by the system when the default value (0000) is
set.
Set the regenerative resistor type. Do not set values without a description.
0 0 0 0 (Default value)
Setting
value
7~F
Set the No. of gear teeth on the motor side and
the No. of gear teeth on the machine side as an
integer reduced to its lowest terms.
Set the total gear ratio if there are multiple gear
levels.
For rotation axes, set the No. of motor rotation
speed per machine rotation.
Set 360 (default value) for rotation axes.
Set the feed lead for linear axes.
In-position is detected when the position droop
becomes this setting value or less.
II - 325
Amplifier standard built-in resistor (10CT
0
has no built-in resistor)
1
Setting prohibited
2
MR-RB032 (30W)
3
MR-RB12 (100W)
4
MR-RB32 (300W)
5
MR-RB30 (300W)
6
MR-RB50 (500W)
Default
Setting range
value
0000 to FFFF
0000
(hexadecimal)
Details
1 to 32767
1
1 to 32767
1
1 to 32767
360
(° or mm)
1 to 32767
50
(1/1000° or µm)

Advertisement