Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 416

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

11. Macro List
#
Item
7001
M [01]
to
to
7091
M [10]
7002
to
7092
7003
to
7093
M2mac
7102
7103
#
Item
7201
G [01]
to
to
7291
G [10]
7202
to
7292
7203
to
7293
Smac
7302
7303
Tmac
7312
7313
11. Macro List
(SETUP PARAM 7. 1/3)
Details
<Code>
Set the M code used for calling out the macro with
the M command.
This is valid when #1195 Mmac is set to 1.
<Type>
Set the macro call out type.
0
M98 P∆∆∆∆; and equivalent value call
1
G65 P∆∆∆∆; and equivalent value call
2
G66 P∆∆∆∆; and equivalent value call
3
G66.1 P∆∆∆∆; and equivalent value call
others
M98 P∆∆∆∆; and equivalent value call
<Program No.>
Set the No. of the program to be called out.
Set the type and program No. for when calling out the macro with the 2nd
miscellaneous command. The macro will be called out with the #1170
M2name address command when #1198 M2mac is set to 1.
<Type>
Same as the M call macro.
<Program No.>
Same as the M call macro.
(SETUP PARAM 7. 2/3)
Details
<Code>
Set the G code to be used when calling the macro
with a G command. Do not set a G code used in the
system.
<Type>
Same as the M call Marco.
<Program No.>
Same as the M call Marco.
Set the type and program No. for when calling the macro with an S
command.
This is valid when #1196 Smac is set to 1.
<Type>
Same as the M call Marco.
<Program No.>
Same as the M call Marco.
Set the type and program No. for when calling the macro with a T command.
This is valid when #1197 Tmac is set to 1.
<Type>
Same as the M call macro.
<Program No.>
Same as the M call macro.
II - 320
Setting range (unit)
1 to 9999
0 to 3
1 to 99999999
0 to 3
0 to 99999999
Setting range (unit)
1 to 255
0 to 3
1 to 99999999
0 to 3
1 to 99999999
0 to 3
0 to 99999999

Advertisement

loading