5. Base Specifications Parameters
After setting up the parameter (PR) listed in the table, turn OFF the NC power. To validate the parameter,
turn ON the power again.
#
Items
1001
SYS_ON
System
(PR)
validation
setup
1002
axisno
Number of
(PR)
axes
1003
iunit
Input setup
(PR)
unit
1013 axname
Axis name Specify each axis' name address with an alphabetic
1014 incax
Increment
command
axis name
1015
cunit
Command
(PR)
unit
5. Base Specifications Parameters
(SETUP PARAM 1. 1/15)
Details
Specify the existence of the 1st system‚ 2nd system
and PLC axis with 1 or 0.
Set No. of axes in each system and the No. of PLC
axes.
Specify 6 as the maximum value for each system
and 4 as that for the PLC axis so that the total of
those values is 6 or less.
Specify the input setting value for each system and
the PLC axis. The parameter units will follow this
specification.
character.
Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C.
Do not specify the same address in one system.
The same address can be specified for the 1st and
2nd system.
The PLC address does not need to be set. (The axis
name is displayed as 1 and 2.)
When specifying the program movement rate's
absolute or incremental method with an address‚
specify the incremental command axis name
address with an alphabetic character.
The address that can be used is the same as #1013
axname.
Specify an address that is different from that #1013.
Setting is not required if absolute/incremental
specification with addresses is not performed
(#1076 Abslnc = 0).
Specify the minimum unit of the program movement
amount.
cunit Movement amount for movement
command 1
0: Follow #1003 iunit
1: 0.0001 mm ( 0.1
10: 0.001 mm (
1
100: 0.01
mm ( 10
1000: 0.1
mm (100
10000: 1.0
mm
If there is a decimal point in the movement
command‚ the decimal point position will be handled
as 1mm regardless of this setting.
II - 23
μ
m)
μ
m)
μ
m)
μ
m)
Setting range (unit)
0: Not used
1: Used
0 to 6
μ
B: 1
m
μ
C: 0.1
m
μ
D: 0.01
m
Axis addresses such as
X, Y, Z, U, V, W, A, B,
and C
0
#1003 iunit
μ
1
0.1
m
μ
10
1
m
μ
100
10
m
μ
1000
100
m
10000
1 mm

Advertisement

loading