Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 406

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

(3) Fig. 2. 3 contains a machine position that is placed in the negative direction with respect to the reference
point. Assume that feed from division point n+1 to n by the division interval is executed. In this case‚ the
following value is defined as the compensation amount:
(Division interval + Actual movement distance) × 2 (Unit of output)
n-1
1
Fig. 2. 2
Unit
: Unit of output
Range
: -128 to 127
(Note) The unit of output is used as the unit of setting. The actual unit of compensation pulses depends on
the compensation scale factor.
9. Mmachine Error Compensation
9.2 Setting Compensation Data
n
n
1
n+1
n: Division point compensation number
1: Division interval
Fig. 2. 3
II - 310