Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 309

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

8.1 MDS-B-SP/SPH, SPJ2 Spindle Base Specifications Parameters
#
Items
3055 sptc2
Spindle
synchroniza-
tion multi-step
acceleration/
deceleration
changeover speed
2
3056 sptc3
Spindle
synchroniza-
tion multi-step
acceleration/
deceleration
changeover speed
3
3057 sptc4
Spindle
synchroniza-
tion multi-step
acceleration/
deceleration
changeover speed
4
3058 sptc5
Spindle
synchroniza-
tion multi-step
acceleration/
deceleration
changeover speed
5
3059 sptc6
Spindle
synchroniza-
tion multi-step
acceleration/
deceleration
changeover speed
6
8. MDS-B-SP/SPH, SPJ2 Spindle Parameters
Set the spindle speed for changing the 2nd
step's acceleration/deceleration time
constant.
Set the spindle speed for changing the 3rd
step's acceleration/deceleration time
constant.
Set the spindle speed for changing the 4th
step's acceleration/deceleration time
constant.
Set the spindle speed for changing the 5th
step's acceleration/deceleration time
constant.
Set the spindle speed for changing the 6th
step's acceleration/deceleration time
constant.
II - 213
Details
Setting range (Unit)
0 to 99999 (r/min)
0 to 99999 (r/min)
0 to 99999 (r/min)
0 to 99999 (r/min)
0 to 99999 (r/min)

Advertisement