No.
Items
3407 SP207 GDL
3408 SP208 W2
3409
SP209
to
to
3413
SP213
3414 SP214 TZRN
3415 SP215 TPDT
3416 SP216 TPST
8. Spindle Parameters
8.4 MDS-C1-SPM
Sequential
To carry out spindle synchronization or C-axis
mode startup
control in the both-chuck state with no
timing
movement immediately after the power is
turned ON, set this parameter so that the
reverse run detection function will function
correctly. Set so that servo ON timing for the
opposing spindle has the combination of (1)
and (2) shown in the drawing below.
0: Servo turns ON simultaneously with servo
ON command, and servo ON status is
returned immediately.
1: Gate turns ON at pattern (1) shown below,
and servo ON status is returned two
seconds later.
2: Gate turns ON at pattern (2) shown below,
and servo ON status is returned two
seconds later.
Servo ON command
Servo ON (1)
Servo ON (2)
Servo ON status
This is used by Mitsubishi.
Set to "0" unless particularly designated.
Not used. Set to "0".
Synchronized
This parameter is valid when SP193 (SPECT)
tapping
bitE is set to "0".
zero point
Set the zero point return speed used when
return speed
the speed loop changes to the position loop.
Synchronized
This parameter is valid when SP193 (SPECT)
tapping
bitE is set to "0".
zero point
Set the deceleration rate where the machine
return
starts to decelerate when it returns to the
deceleration
target stop point during synchronized tapping
rate
zero point return.
When the machine tends to overshoot at the
stop point set a smaller value.
Synchronized
This parameter is valid when SP193 (SPECT)
tapping
bitE is set to "0".
zero point
Set the synchronized tapping zero point
return shift
position.
amount
Details
Gate ON
700ms
300ms
II - 296
Setting
range
0/1/2
0
Servo ON
300ms
Gate ON
700ms
2s
0
0
0
0
0 to 10000
1
(pulse)
0 to 4095
0