Error No.
Error message
E86
INPUT DATA ERR
E87
NOT EDIT PROG.
E88
CAN'T ADD
BLOCK
E91
MODE ERROR
(PBK)
E98
CAN'T
RESEARCH
E165
AUX RUNNING
E190
FORE EDITING
E191
NOT COM.
SEARCH
E200
ADJUST ERROR
2. Operation Messages on Setting And Display Unit
2.1 Operation Errors
×
• When inputting the tool offset data‚ the data format was not
correct‚ so that block could not be input.
• If the INPUT key is pressed again in the input screen‚ the input
will continue from the next block.
• When data is read from parameter tape, its format is incorrect.
• The format of file written to the NC memory is illegal.
×
• Playback edit was executed for a fixed cycle subprogram.
Playback edit of a fixed cycle subprogram is not possible.
×
• Playback edit cannot be executed unless the block being edited
with playback is displayed to the end (EOB) on the left side of the
machining program display area. Press the cursor key
display the whole block to the end. Then‚ input the data.
×
• G90 was set when "PB_G90" was OFF.
• G91 was set when "PB_G90" was ON.
×
• When restarting the program, the type 3 restart search was
attempted with a program containing no T command. Check the
program.
• When restarting the program, the T command corresponding to
the type 3 restart search was not found in the program. Check
the program.
• When restarting a program for 2-systems, restart search was
performed simultaneously for the 1st and 2nd systems, and then
the 2nd system was searched again.
If program restart is continued (if the axis is return to the restart
position with automatic or manual operations), the program will
restart from the block searched for first.
To search again, cancel the previous search by resetting, and
then search again.
• When carrying out program restart, restart search 2 was
executed during MDI mode. Change to the memory or tape, and
search again.
• When carrying out program restart, type 3 restart search was
attempted while the machine was at the negative (-) side of the
restart limit parameters. Manually move the machine to the
positive (+) side of the restart limit parameters, and search again.
×
• The keys other than Function/Menu/Previous page/Next page
were pressed in Auxiliary monitor screen during auxiliary axis
operation.
×
• An attempt was made to perform background search for the
program that is in foreground search status. (Word editing)
×
• Operation search was attempted in tape mode.
×
• The hardware status can't be read correctly‚ so automatic
adjustment was not possible.
• Check the remote l/O unit.
• A Z55 RIO NOT CONNECT occurred.
• Adjust manually.
• Unit defect (replace unit)
Details