Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 207

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

#
Items
2095 plG1t1
G1 time
constant for
superimposi-
tion control
(primary
delay)
2096 crncsp
Minimum
corner
deceleration
speed
2099 igConr
Axis excluded
from corner
angle
calculation
2102 skip_tL Skip time
constant
linear
2103 skip_t1 Skip time
constant
primary delay
acceleration
and
deceleration
by software
second stage
6. Axis Specifications Parameters
6.4 Axis Specifications Parameters 2
Set the G1 time constant (primary delay) for
superimposition control.
(Equivalent to #2008 G1t1 (G1 time constant (primary
delay).)
Set the minimum clamp speed for corner deceleration
during the high-accuracy control mode. Normally set
"0".
Note: This parameter is invalid during SSS control.
Set the axis excluded from the corner angle calculation.
For example, set this for the Cs axis during spring
machining.
Set up a linear control time constant for variable speed
skip acceleration and deceleration.
The time constant is validated when LC (cutting feed
with linear acceleration and deceleration) or F
(acceleration and deceleration by software) is selected
in acceleration or deceleration mode "#2003 smgst".
Set up a primary-delay time constant for variable speed
skip acceleration and deceleration.
The time constant is validated when C1 (cutting feed
with primary delay) or C3 (exponential acceleration and
linear deceleration) is selected in acceleration or
deceleration mode "#2003 smgst".
When acceleration or deceleration by software is
selected, the second-step time constant is used.
II - 111
Details
Setting range (unit)
1 to 5000 (ms)
0 to 1000000
(mm/min)
0/1
1 to 4000 (ms)
1 to 5000 (ms)

Advertisement

loading