(9) M01 AUX OPER. ALM
Alarm
Details
information
No operation mode The operation mode is not
0101
Feedrate 0
0103
Station No.
0160
designation illegal.
Starting not
possible.
Reference point
0161
return incomplete.
Starting not
possible.
In initializing
0162
reference point.
Starting not
possible.
In absolute
0163
position alarm.
Starting not
possible.
In random
0164
positioning mode.
Manual operation
not possible.
Uneven indexing
0165
station No. illegal.
Starting not
possible.
1. List of Alarms
1.8 Auxiliary Axis Alarms
Cause
designated, or the operation
mode was changed during axis
movement.
The operation parameter's
feedrate setting is zero.
The operation parameter
feedrate setting is zero.
Or, the override is valid, and the
override value is zero.
A station No. exceeding the No.
of indexed divisions was
designated.
Automatic/manual operation was
started before reference point
return was executed with the
incremental system.
The start signal was input while
initializing the absolute position
reference point.
The start signal was input during
an absolute position alarm.
The manual operation mode was
started during the random
positioning mode.
The commanded station No. was
higher than 9 or the number of
indexing stations during uneven
indexing.
I - 42
Remedy
• Correctly designate the operation
mode.
• Set a value other than zero in the
feedrate setting or override value.
• Correctly designate the station
No.
• Execute the reference point
return.
• Complete the absolute position
reference point initialization.
• Initialize the absolute position
reference point and then fix the
absolute position coordinates.
• Turn the random positioning
mode OFF before switching to
the manual operation mode.
• Check the commanded station
No. and the parameter "#100
station" setting.