7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
(1) Details for servo parameters
For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned
ON again, the parameter is validated.
!
CAUTION
In the explanation on bits, set all bits not used, including blank bits, to "0".
!
No.
Items
2201
SV001
Motor side gear
(PR)
PC1
ratio
2202
SV002
Machine side
(PR)
PC2
gear ratio
2203 SV003
Position loop
PGN1
gain 1
2204 SV004
Position loop
PGN2
gain 2
2205 SV005
Speed loop
VGN1
gain 1
2206 SV006
Speed loop
VGN2
gain 2
7. Servo Parameters
7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Set the motor side and machine side gear ratio.
For the rotary axis, set the total deceleration
(acceleration) ratio.
Even if the gear ratio is within the setting range, the
electronic gears may overflow and cause an alarm.
Set the position loop gain. The standard setting is
"33 ".
The higher the setting value is, the more precisely
the command can be followed and the shorter the
positioning time gets, however, note that a bigger
shock is applied to the machine during
acceleration/deceleration.
When using the SHG control, also set SV004
(PGN2) and SV057 (SHGC). (If "201 " or bigger is
set, the SHG control cannot be used.)
When using the SHG control, also set SV003
(PGN1) and SV057 (SHGC).
When not using the SHG control, set to "0".
Set the speed loop gain.
Set this according to the load inertia size.
The higher the setting value is, the more accurate
the control will be, however, vibration tends to occur.
If vibration occurs, adjust by lowering by 20 to 30%.
The value should be determined to be 70 to 80% of
the value at the time when the vibration stops.
If the noise is bothersome at high speed during rapid
traverse, etc, lower the speed loop gain.
As in the right figure, set the speed loop gain of the
speed 1.2 times as fast as the motor's rated speed,
and use this with SV029 (VCS).
When not using, set to "0".
VGN1
VGN2
0
Details
VCS
VLMT
(Rated speed*1.2)
II - 141
Setting range
1 to 32767
1 to 32767
1 to 200
(In case of
MDS-B-Vx4,
1 to 400)
(rad/s)
0 to 999
(rad/s)
1 to 999
-1000 to 1000