2007 G1tL
G1 time
constant
(linear)
2008 G1t1
G1 time
constant
(primary delay)
Second stage
time constant
for acceleration
and
deceleration by
software
2009 G1t2
6. Axis Specifications Parameters
6.1 Axis Specifications Parameters
Set up a linear control time constant for cutting
acceleration and deceleration.
The time constant is validated when LC (cutting feed
with linear acceleration and deceleration) or F
(acceleration and deceleration by software) is
selected in acceleration or deceleration mode "#2003
smgst".
Speed
G1tL
Set up the primary delay time constant for cutting
acceleration and deceleration.
The time constant is validated when C1 (cutting feed
with the primary delay) or C3 (cutting feed with
exponential acceleration and linear deceleration) is
selected in acceleration or deceleration mode "#2003
smgst".
When acceleration or deceleration by software is
selected, the second stage time constant is used.
<Cutting feed with primary time constant>
Speed
G1t1
<Cutting feed with exponential acceleration
and linear deceleration>
Speed
G1t1
Not used.
II - 95
Details
Time
G1tL
Time
G1t1
Time
2 G1t1
Setting range (unit)
1 to 4000 (ms)
1 to 5000 (ms)
0

Advertisement