Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 139

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

#
Items
1133 ofsmem
Select how to
set up tool
wear
compensa-
tion screen
1134 LCDneg
LCD reverse
display
1135 unt_nm
Unit name
1136 optype
Operation
menu display
valid
1137 Cntsel
Coordinate
value screen
display
counter
select
1138 Pnosel
Select
screen by
parameter
number:
5. Base Specifications Parameters
Details
Select the number stored by previous setup when
selecting the tool wear compensation screen.
0: Does not display the number when selecting
the screen.
1: Displays the stored number when selecting the
screen.
Specify 1 to reverse the display on the 10.4-type
monochrome LCD.
Set up a unit name.
Set up the unit name with 4 or less characters
consisting of both alphabets and numbers. If 0 is set
up, the unit name is not displayed.
This parameter validates the operation menu display.
Specify the setting method for the tool offset data's
absolute value or incremental value.
0: Mode selection method
(Conventional specification)
1: Menu selection method
This parameter is valid on the following screens.
• TOOL TIP OFFSET screen (L system)
• TOOL DATA screen (L system)
• NOSE-R screen (L system)
• TOOL OFFSET screen type I (M system)
• TOOL OFFSET screen type II (M system)
Set the type of the position counter to be displayed on
the COORDINATE screen.
0
: MST (Default)
1
: Next command
2
: Current value B
3
: Manual interrupt amount
0 or 1 : Next value (Default)
2
: Current value B
3
: Manual interrupt amount
Specify whether to enable the function to select a
screen by specifying a parameter number.
II - 43
Setting range (unit)
0/1
0: Normal display
1: Reverse display
4 or less characters
consisting of both
alphabets and
numbers
0/1
1st digit : 0 to 3
2nd digit: 0 to 3
(Default : 00)
0: Disable
1: Enable

Advertisement