Z71 DETECTOR ERROR
Error No.
Details
The backup voltage in the
0001
absolute position detector
dropped.
Communication with the
0003
absolute position detector
was not possible.
The absolute position
0004
data fluctuated when
establishing the absolute
position.
An error was found in the
0005
serial data from the
absolute position
detector.
Servo alarm E3
0006
Absolute position counter
warning
Initial communication with
0007
the absolute position
detector was not
possible.
1. List of Alarms
1.6 Absolute Position Detection System Alarms
(Error No.) (Axis name)
Remedy
Replace the battery‚
check the cable
connections‚ and
check the detector.
Turn the power ON
again‚ and perform
zero point
initialization.
Check and replace the
cables‚ card or
detector. Turn the
power ON again‚ and
perform zero point
initialization.
Check and replace the
cables‚ card or
detector. Turn the
power ON again‚ and
perform zero point
initialization.
Check and replace the
cables‚ card or
detector. Turn the
power ON again‚ and
perform zero point
initialization.
Operation is possible
until the power is
turned off.
Check and replace the
cables‚ card or
detector. Turn the
power ON again‚ and
perform zero point
initialization.
This alarm is displayed if an error is found in
the detector for the absolute position detection
system.
Zero point
initialization
Required
(Required) Only
when detector is
replaced.
(Required) Only
when detector is
replaced.
(Required) Only
when detector is
replaced.
(Required) When
power is turned ON
again.
(Required) Only
when detector is
replaced.
I - 33
Alarm reset
when
Servo
power is
alarm No.
turned OFF
25
(Z70-0101
displays
after power
is turned
ON again.)
Reset
91
Reset
93
Reset
92
Reset
E3
(Z70-0106
displays
after power
is turned
ON again.)
Reset
18