2. Machining Parameters
2.1 Process Parameters
<WRK COUNT> (No. of workpieces machined)
#
Item
8001 WRK COUNT M
8002 WRK COUNT
8003 WRK LIMIT
<AUTO TLM> (Automatic tool length measurement)
#
Item
8004 SPEED
8005 ZONE r
8006 ZONE d
<AUTO CORNER OVR> (Automatic corner override)
#
Item
8007 OVERRIDE
8008 MAX ANGLE
8009 DSC. ZONE
<T-TIP OFFSET> (Wear data input)
#
Item
8010 ABS. MAX.
(For L system only)
8011 INC. MAX.
(For L system only)
2. Machining Parameters
2.1 Process Parameters
Contents
Set the M code that counts the No. of workpiece
repeated machining.
The No. will not be counted when set to 0.
The current machining No. is displayed. Set the
initial value.
Set the maximum No. of workpieces machined.
A signal is output to PLC when the No. of machining
times is counted to this limit.
Contents
Set the feedrate during automatic tool length
measurement.
Set the distance between the measurement point
and deceleration start point.
Set the tolerable zone of the measurement point.
If the sensor signal turns ON in front of d before the
measurement point‚ or if the signal does not turn ON
after d is passed‚ an alarm will occur.
Contents
Set the override value for automatic corner override. 0 to 100 (%)
Set the max. corner opening angle where
deceleration should start automatically.
If the angle is larger than this value‚ deceleration will
not start.
Set the position where deceleration starts at the
corner.
Designate at which length point before the corner
deceleration should start.
Contents
Set the max. value when inputting the tool wear
compensation amount.
A value exceeding this setting value cannot be set.
Set the max. value for when inputting the tool wear
compensation amount in the incremental mode.
II - 3
Setup range (unit)
0 to 99
0 to 999999
0 to 999999
Setup range (unit)
1 to 60000 (mm/min)
0 to 99999.999 (mm)
0 to 99999.999 (mm)
Setup range (unit)
0 to 180 (°)
0 to 99999.999 (mm)
Setup range (unit)
0 to 999.999 (mm)
0 to 999.999 (mm)

Advertisement