Mitsubishi Electric MELDAS 60 Series Parameter Manual page 330

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

No.
Items
3434
SP234 OBS1
(PR)
3435
SP235 OBS2
(PR)
3436
SP236
to
to
3452
SP252
3453 SP253 DA1NO
3454 SP254 DA2NO
3455 SP255 DA1MPY DA output
3456 SP256 DA2MPY DA output
8. Spindle Parameters
8.2 MDS-B-SPJ2
Disturbanc
Set the frequency of the low path filter for
e observer
when the disturbance observer is valid.
low path
Setting (1/s) = 2πf
filter
f: Approx. 1.5 times the disturbance
frequency
Disturbanc
Set the gain for the disturbance observer.
e observer
gain
Not used. Set to "0".
D/A output
Set the output data number for channel 1 of
channel 1
the D/A output function.
data
When the setting value is "0", the output is
number
speedometer.
Refer to "8.5.1 D/A Output Specifications".
D/A output
Set the output data number for channel 2 of
channel 2
the D/A output function.
data
When the setting value is "0", the output is
number
load meter.
Refer to "8.5.1 D/A Output Specifications".
Set the data magnification for channel 1 of
channel 1
the D/A output function.
magnifica-
The output magnification is (setting
value)/256.
tion
When set to "0", the output magnification
becomes 1-fold, in the same manner as
when "256" is set.
Refer to "8.5.1 D/A Output Specifications".
Set the data magnification for channel 2 of
channel 2
the D/A output function.
magnifica-
The output magnification is (setting
value)/256.
tion
When set to "0", the output magnification
becomes 1-fold, in the same manner as
when "256" is set.
Refer to "8.5.1 D/A Output Specifications".
Details
frequency
II - 234
Setting
Standard
range
setting
0 to 1000
0
(1/s)
0 to 500
0
(%)
0
0
-32768 to
0
32767
-32768 to
0
32767
-32768 to
0
32767
(1/256-fold)
-32768 to
0
32767
(1/256-fold)