Download Print this page

Mitsubishi Electric MELDAS 60 Series Parameter Manual page 399

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

(2) Setting the output data
Input the No. of the data to be output to each D/A output channel.
#
No.
3453
SP253
3454
SP254
No.
Output data
ch1: Speed meter
output
0
ch2: Load meter
output
1
-
Current command Rated 100% = 4096
2
Current feedback Rated 100% = 4096
3
4
Speed feedback
5
-
6
Position droop
7
-
Feedrate (F∆T)
8
9
-
10 Position command 1° = (64000/65536)
11 -
12 Position feedback 1° = (64000/65536)
13 -
80 Control input 1
81 Control input 2
82 Control input 3
83 Control input 4
84 Control output 1
85 Control output 2
86 Control output 3
87 Control output 4
8. Spindle Parameters
8.5 Supplement
Abbrev
DA1NO
D/A output channel 1 data No.
DA2NO
D/A output channel 2 data No.
Original data unit
10V=max. speed
(0=0V)
10V=120% load (0=0V) 0
r/min
1° = (64000/65536)
1° = (64000/65536)
HEX
HEX
II - 303
Parameter name
Standard setting value
for output scale
(Setting values in
SP255, SP256)
0
8
8
13
671
629
(When communicating
by 3.5ms)
19 (18.64)
19 (18.64)
Bit correspondence
Bit correspondence
Standard
output unit
Depends on
the max.
speed
Rated
12%/V
Rated
20%/V
Rated
20%/V
500(r/min)/V
10°/V
500(r/min)/V
360°/V
360°/V

Advertisement

loading