Mitsubishi Electric MELDAS 60 Series Parameter Manual page 324

Cnc
Hide thumbs Also See for MELDAS 60 Series:

Advertisement

No.
Items
3313
SP113 WINP
(PR)
3314 SP114 OPER
3315 SP115 OSP2
3316 SP116 OPYVR
3317 SP117 ORUT
3318 SP118 ORCT
3319
SP119
to
to
3376
SP176
8. Spindle Parameters
8.2 MDS-B-SPJ2
Turret index
The position error range is set in which an
in-position
orientation (indexing) completed signal is
width
output during turret indexing. This
becomes the same as SP004 (OINP)
when set to "0".
Orientation
An alarm "5C" will occur if the pulse miss
pulse miss
value in the orientation stop exceed this
check value
setting value. (Note that this is invalid
when set to "0".)
In this parameter, set the value to fulfill the
following conditions.
SP114 setting value > 1.5 × SP004
(orientation in-position width)
Orientation
When the door interlock spindle speed
changeover
clamp signal is ON, this setting is used
speed limit
instead of OSP(SP005), CZRN(SP149)
value 2
and TZRN(SP214). (Note that SP149 and
SP214 are used only for the M65V.)
Fixed control
Set by Mitsubishi.
constants
Set "0" unless designated in particular.
Number of
Set the number of times to retry when an
orientation
orientation or feedback error occurs.
retry times
The warning (A9) is issued while retrying
orientation, and an alarm (5C) is issued
when the set number of times is
exceeded.
Not used. Set to "0".
Details
II - 228
Setting
Standard
range
setting
0 to 32767
0
(1/16°)
0 to 32767
0
(360°/4096)
0 to 32767
0
(r/min)
0
0
0 to 100
0
(time)
0
0