3.3 Computer Link Parameters
#
Item
9601 BAUD RATE
9602 STOP BIT
9603 PARITY EFFECTIVE
9604 EVEN PARITY
9605 CHR. LENGTH
9606 HAND SHAKE
9607 TIME-OUT SET
9608 DATA CODE
3. I/O Parameters
3.3 Computer Link Parameters
Contents
Specify the rate at which data is transferred.
Specify stop bit length used in start-stop mode. See
"PARITY EFFECTIVE" in #9603. The number of
characters is adjusted in output mode so that no
problems occur if the parity check is enabled.
This parameter is set when using a parity bit
separately from the data bit.
1 character
ON
b1 b2 b3 b4 b5 b6
OFF
Start bit
Data bit
Set this to match the input/output device
specifications.
Specify whether even or odd parity is used when
parity is used. This parameter is ignored when no
parity is used.
Specify data bit length.
See "PARITY EFFECTIVE" in #9603.
RS-232C transmission control mode
DC control mode should be set for computer line B.
Specify time-out time at which an interruption of
data transfer during data input/output should be
detected.
If 0 is set, time infinity is specified.
Specify the code to be used.
See "PARITY EFFECTIVE" in #9603.
II - 20
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5:
6:
7:
8: 38400
1: 1
2: 1.5
3: 2
0: No parity bit used in
1: Parity bit used in I/O
bn
Parity bit
Stop bit
0: Odd parity
1: Even parity
2: 7
3: 8
0: No control
1: RTS/CTS method
2: No handshaking
3: DC control mode
0 to 999 (1/10s)
0: ASCII code
1: ISO code
Setup range (unit)
600
300
110
I/O mode